Product Details
ICM Controls ICM277 Fan Blower Control Board – Goodman OEM Replacement ControlUpon application of power to the G terminal, the ICM277 recognizes a call for the blower and a 7 second delay on make period begins. After the 7 second ON delay, the control energizes the blower motor. Upon removal of power from the G terminal, the board will keep the blower on for an additional 65 seconds. At the end of the 65 second OFF delay, the blower will shut off.Microprocessor-based precisionFor circulating fan in heat pump, A/C and forced air systemsFan post purge timer to control circulating fan in forced air systemsDual function 7 second ON delay / 65 second OFF delaySpeed up terminals for test modeFuse protected control voltageHigh power relay outputSPECIFICATIONSInput:Voltage: 18-30 VACContact Ratings:N.O.: 20 ampsN.C.: 10 ampsFixed Time Delays:Blower ON: 7 seconds fixedBlower OFF: 65 seconds fixedREPLACESGoodman- B1370735S, PCBFM131SICM277 Installation InstructionsICM277 Data Sheet